Reference levels for the general public from [11]. |
||||
| Council Recommendation of 12 July 1999 Reference levels for electric, magnetic and electromagnetic fields (0 Hz to 300 GHz, unperturbed rms values) |
||||
|
|
||||
| Frequency range |
E-field strength (V/m) |
H-field strenght (A/m) |
B-field (μT) |
Equivalent plane wave power density Seq (W/m2) |
|
|
||||
| 0–1 Hz |
- |
3,2 × 104 |
4 × 104 |
- |
| 1–8 Hz |
10 000 |
3,2 × 104/f2 |
4 × 104/f2 |
- |
| 8–25 Hz |
10 000 |
4 000/f |
5000/f |
- |
| 0,025–0,8 Hz |
250/f |
4/f |
5/f |
- |
| 0,8–3 kHz |
250/f |
5 |
6,25 |
- |
| 3–150 kHz |
87 |
5 |
6,25 |
- |
| 0,15–1 MHz |
87 |
0,73/f |
0,92/f |
- |
| 1–10 MHz |
87/f1/2 |
0,73/f |
0,92/f |
- |
| 10–400 MHz |
28 |
0,073 |
0,092 |
2 |
| 400–2 000 MHz |
1,375 f1/2 |
0,0037 f1/2 |
0,0046 f1/2 |
f/200 |
| 2–300 GHz |
61 |
0,16 |
0,20 |
10 |
Di Nallo et al. Journal of Experimental & Clinical Cancer Research 2008 27:16 doi:10.1186/1756-9966-27-16 |
||||